Troubleshoot
Table Of Contents
- TROUBLESHOOTING GUIDE
- ELECTRIC INSTANTANEOUS TANKLESS WATER HEATER
- GENERAL
- If the unit now operates with water flowing, call Technical Service at
- Make sure the printed circuit board is mounted in the correct position. This is the top set of mounting holes (See diagram below). Failure to mount the PCB in the correct position will cause element burn out and may cause further damage to the unit (This board may have been incorrectly positioned if serviced previously).
- GENERAL
- ELECTRIC INSTANTANEOUS TANKLESS WATER HEATER
STEP THREE:
In the brass outlet
fitting there is a flow restrictor, this is a little black plug.
Shut the water off to the unit and then remove the plug from the fitting. Open
the faucet fully to see if the light illuminates with water flowing through the
unit.
0.5 gpm flow regulator
(The little black plug)
INLET
OUTLET
SP MODELS
UP
inlet filter
If the unit now operates with water flowing, call Technical Service at
1-800-334-3393. Describe what actions were taken and a selection of “flow
restrictors” will be sent to you to replace the one that was removed. This will allow
the unit to operate, but will also control the flow rate to provide the correct rise in
temperature.
If the unit still does not work proceed to step 4.