Service Manual

Specifications
Venting Specifications for:
48 Gallon
65 Gallon
Through the Wall
Terminating
# of
Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
3" Diameter (7.6 cm) PVC Vent Connector Lengths
1 55 (16.8) 2 (.6)
Through the Wall 2 50 (15.2) 2 (.6)
Through the Wall 3 45 (13.7) 2 (.6)
Through the Wall 4 40 (12.2) 2 (.6)
Through the Wall
Terminating
# of
Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
4" Diameter (10.2 cm) PVC Vent Connector Lengths
1 10 (3.1)
Through the Wall 2 10 (3.1)
Through the Wall 3 10 (3.1)
Through the Wall 4 10 (3.1)
Through the Roof 0 60 (18.3) 7 (2.1)
Through the Roof 1 55 (16.8) 7 (2.1)
Through the Roof 2 50 (15.2) 7 (2.1)
Through the Roof 3 45 (13.7) 7 (2.1)
Through the Roof 0 15 (4.6)
Through the Roof 1 15 (4.6)
Through the Roof 2 15 (4.6)
Through the Roof 3 15 (4.6)
Through the Wall 5 12 (3.6)
Through the Roof 4 15 (4.6)
Vent Tables
Page 8
175 (53.3)
170 (51.8)
165 (50.3)
160 (48.8)
180 (54.9)
175 (53.3)
170 (51.8)
165 (50.3)
155 (47.2)
160 (48.8)
Page 8