2 2384975400B2/12
Step1:ThoroughlyreadandunderstandtheventingsectionoftheInstallationandOperatingInstructionManualthat
wassuppliedwiththewaterheaterbeforedeterminingthelocationofthewaterheaterandtheventterminals.Locate
thewaterheaterfortheshortestpracticalventlengthtotheoutside.Measurethetotalventingdistancerequiredto
reachtheoutsidewallorroof.Determinethediameteroftheventingcomponents
touseforthelengthofventpipe
(andcombustionairsupplyfordirectventmodels)requiredbyreferringtotheventingtablesintheinstructionmanual
forthemaximumventlengthforeachdiameterpipesize.Obtainallthenecessaryventingsystemcomponentsforthe
installation.
Step2:Before
installation,inspecteachventcomponentfordamagemakingsurethegaske tsforeachcomponentare
fullyintactandinundamagedcondition.Donotattempttoinstallorrepairdamagedcomponents.Ifagasketis
damaged,theseareavailablefromthesupplierofCentrothermInnofluecomponents.Donotusegasketsfromanother
manufactureranddonottrytorepairthegasket.
Step3:ACentrothermPVC
toPolypropyleneadapter(CentrothermISAGLpartseries)mustbeusedtoconnectintoa
PVCcouplingortee(CommercialandResidentialPowerDirectVentairintakeconnections),condensateelbow(High
EfficiencyCommercialCondensingmodels)ortheexhaustoutletadapterforCommercialPowerDirectVentand
ResidentialPowerVentedmodels.Tomaketheinsertionofthegasketedfittingsintothecouplingeasie r,Centrocerin
gasketlubricantis
recommended.CentrocerinisawaterbasedlubricantavailablefromyourCentrothermsupplier.If
Centrocerinisnotavailable,watermaybeused.DONOTuseanyotherkindoflubricantwhichmaydamagethe
gaskets.
Applylubricantusingyourfingertothegasketsurfaceandinsideofthecouplingandinsertthemaleendoftheadapter
withtheexteriorgasketintothecoupling,condensate
elboworexhaustoutletadapterconnection.Ifalargervent
diametersizeistobeused,usetheappropriatelysizedreducercouplingfirstonthewaterheaterintakeorexhaustvent
connectionasdetailedintheinstallationmanualsuppliedwiththewaterheater.Seethefollowingphotos.
WARNING
Use only water or Centrocerin lubricant for lubricating the gaskets and pipe ends to allow easy insertion. DO NOT
use any other kind of lubricant, since deterioration of the gasket may result, which may allow dangerous flue gases
to leak into the room. If the vent pipe needs to be disassembled after the gasket has dried, wet the joint thoroughly
to loosen the connection.
HighEfficiencyCondensingCommercialModels:Usetheappropriateprimerandcement(refertoventingsectionof
instructionmanualwithwaterheater)forcementingaPVCcoupling(notsuppliedwithwaterheater)totheendofthe
PVCairintakepipeconnection.ApplyCentrocerinlubricantwithyourfingertothemalegasketedendofthe
CentrothermPVCadapterandfullyinsertintotheairintakecoupling.Loosenthe
Centrothermfluepipeclamp
(Centrothermp/nIAFC03)andinstallontheendofthePVCcouplingsothatthe3clamphookssecurethePVCadapter
tothePVCcoupling.Seefollowingphotos.