Spec Sheet

Commercial Large Volume Jacketed and
Insulated Storage Tanks
The Large Volume Jacketed and Insulated Storage Tank Models
Feature:
Vertical or Horizontal Construction—Horizontal models require two
saddles and have two additional 3" (76mm) NPT fittings.
Steel Jacket—Sturdy heavy gauge steel jacket.
2" (51mm) High Density Foam Insulation—Covers the side and top
of tank, reducing the amount of heat loss. This results in less energy
consumption, improved operation efficiencies, and jacket rigidity.
Vitraglas
®
Lining—An exclusively engineered enamel formula that provides
superior tank protection from the highly corrosive effects of hot water. This
formula (Vitraglas
) is fused to the steel surface by firing at a temperature of
over 1600°F (871°C).
Water Connections—Two female 3" (76mm) NPT fittings are located
on the front for ease of service and installation. Additional size fittings are
available as an option.
Protective Magnesium Anode Rods—Provide added protection against
corrosion for long-term, trouble-free service.
One 3/4" (19mm) NPT Aquastat Fitting—Located in the lower part of the
tank.
Optional Hand Hole Cleanout and Manway—4" x 6" (102mm x 152mm)
diameter Hand Hole cleanout and 12"x16" (305mm x 406mm) diameter
Manway opening allow removal of sediment and inspection of interior
surface.
-- Manway required on all tanks with a vessel diameter of 42" (1067mm)
or greater.
Optional Hydrojet HC
®
Stainless steel, dielectrically isolated recirculation
tube minimizes turbulence and directs the hottest water to the top of the
tank to maximize hot water delivery.
Designed for Storage of Potable Water up to 180°F (82°C).
All Tanks Are Constructed and Certified—In accordance with ASME
Sect. IV, Part HLW for 125 PSI (862 kPa). 150 PSI (1034 kPa) is available as
an option.
Photo is of
NV303JG5A
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821;
6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117;
7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824;
2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas
®
and Hydrojet HC
®
are registered trademarks of Bradford White
®
Corporation.
481-B-1017-A
5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy
of the warranty included with the heater.
Sample Specification:
The storage tank shall be a Bradford White Jacketed and Insulated model with a nominal rated storage capacity of not less than_________gallons (______
liters), and overall dimensions of______ inches (_______cm.) in height, by_________inches (________cm.) in diameter. The tank shall be Vitraglas
®
lined, and
be built in accordance with ASME Boiler and Pressure Vessel Code ASME IV, Part HLW for 125 PSI (862 kPa) and so labeled, with a working pressure of
_________PSI (_________kPa). The storage tank shall have Non-CFC foam insulation and carry a five (5) year limited warranty (ten (10) year limited warranty
available on Double Vitraglas
®
lining).