Installation / Operation Instruction Manual
Table Of Contents
- GAS-FIRED WATER HEATER
- TABLE OF CONTENTS
- Figure 1
- GENERAL OPERATION
- Probable Cause
- Control Status
- LED Status
- Millivolt power is not present. Light pilot.
- None (LED not on or flashing)
- Gas valve is powered and waiting for the set point knob to be turned to a water temperature setting. If the set point knob is at desired setting the thermostat is satisfied.
- If set point knob is in “PILOT” position, then pilot flame is detected. (no faults).
- One flash and three second pause
- LED strobe (two quick flashes) and three second pause
- Water heater operating normally.
- Thermostat calling for heat (no faults).
- Set point knob was recently turn to “OFF” position. Wait until LED goes out before attempting to relight.
- Set point knob has been recently turned to the “OFF” position.
- LED on continuously
- Weak pilot flame detected. System will reset when pilot flame is sufficient.
- Two flashes and three second pause
- Insufficient water heating. System will reset.
- Three flashes and three second pause
- Excessive tank temperature. System must be reset.
- Four flashes and three second pause
- Figure 11
2
CONGRATULATIONS!
You have purchased one of the finest water heaters on the market today!
This installation, operation and instruction manual will explain in detail
the installation and maintenance of your new Flammable Vapor Ignition
Resistant Gas Water Heater. We strongly recommend that you contact a
plumbing professional for the installation of this water heater.
We require that you carefully read this manual, as well as the enclosed
warranty, and refer to it when questions arise. If you have any specific
questions concerning your warranty, please consult the plumbing
professional from whom your water heater was purchased. For your
records we recommend that you write the model, serial number and
installation date of your water heater in the maintenance section in the
back of this manual.
This manual should be kept with the water heater.
Special Flammable Vapor Ignition Resistant System
This water heater is equipped with a Flammable Vapor Ignition Resistant
System. In the event of improper usage or storage of gasoline or other
flammable materials in the location where the water heater is installed, the
technology will resist ignition of the flammable vapors outside the confines of
the water heater.
The Flammable Vapor Ignition Resistant System features:
• Advanced Flame Arrestor Design
• Re-settable Thermal Switch to prevent burner/pilot operation with
restricted airflow
• Piezo Igniter
• Sight Window to observe operation of pilot and burner
FOR YOUR SAFETY: Activation of the Flammable Vapor Ignition Resistant
System occurs when flammable vapors are drawn into the water heater and
are combusted. If flammable vapors are detected:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Leave the premises and immediately call the fire department from a
neighbor’s phone. Follow the fire department’s instructions.
Once the flammable vapor has been evacuated, contact your plumbing
professional or the manufacturer for further instructions. Replacement of a
Flammable Vapor Ignition Resistant System equipped water heater due to a
flammable vapor shutdown is not covered under the terms of the limited
warranty.