Installation / Operation Instruction Manual
Table Of Contents
- GAS-FIRED WATER HEATER
- TABLE OF CONTENTS
- Figure 1
- GENERAL OPERATION
- Probable Cause
- Control Status
- LED Status
- Millivolt power is not present. Light pilot.
- None (LED not on or flashing)
- Gas valve is powered and waiting for the set point knob to be turned to a water temperature setting. If the set point knob is at desired setting the thermostat is satisfied.
- If set point knob is in “PILOT” position, then pilot flame is detected. (no faults).
- One flash and three second pause
- LED strobe (two quick flashes) and three second pause
- Water heater operating normally.
- Thermostat calling for heat (no faults).
- Set point knob was recently turn to “OFF” position. Wait until LED goes out before attempting to relight.
- Set point knob has been recently turned to the “OFF” position.
- LED on continuously
- Weak pilot flame detected. System will reset when pilot flame is sufficient.
- Two flashes and three second pause
- Insufficient water heating. System will reset.
- Three flashes and three second pause
- Excessive tank temperature. System must be reset.
- Four flashes and three second pause
- Figure 11
28
Troubleshooting continued-
Contact your supplier or plumbing professional for replacement parts or
contact the company at the address given on the rating plate of the water
heater.
Provide the part name, model and serial numbers of the water heater when
ordering parts.
READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH
OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED.
Complete the following information and retain for future reference:
Model No: ___________________________________________________
Serial No: ___________________________________________________
Service Phone
Days: __________________ Nights: _____________________________
Address: _____________________________________________________
Supplier: ____________________________________________________
Supplier Phone No: ____________________________________________
CAUTION
FOR YOUR SAFETY, DO NOT ATTEMPT REPAIR OF COMBINATION
GAS CONTROL, BURNERS OR GAS PIPING. REFER REPAIRS TO A
QUALIFIED SERVICE TECHNICIAN.
Manufactured under one or more of the following U.S. Patents: 5,277,171;
5,341,770; 5,372,185; 5,485,879; 5,574,822; 5,596,952; 5,660,165;
5,682,666; 5,761,379; 5,943,984; 5,954,492; 5,988,117; 6,056,542;
6,142,216; 6,442,178; 6,684,821; 6,935,280; 7,063,132; 7,063,133;
7,007,748; 7,270,087; 7,334,419; 7,337,517; 7,409,925; 7,458,341;
7,559,293; 7,621,238; 7,634,976; 7,650,859; 7,665,210; 7,665,211;
7,699,026; 7,866,168; 7,900,589; 7,971,560; 7,992,526 8,082,888;
8,146,772; Other U.S. and Foreign patent applications pending. Current
Canadian Patents: 2,092,105; 2,107,012; 2,108,186; 2,112,515; 2,143,031;
2,239,007; 2,262,174; 2,314,845; 2,409,271; 2,476,685; 2,504,824;
2,548,958