Vent Kit Installation Manual
Table Of Contents
Scope of Delivery
Concentric Horizontal Vent Kit – 6 720 812 236 (2014/05)
4
2Scope of Delivery
Fig. 1 Scope of delivery - dimensions in inches (mm)
[1] 90° elbow
[2] Telescopic terminal assembly
[3] Inner wall seal
[4] Outer wall seal
[5] Screws and wall anchors
[6] Connecting screws
[7] Securing screws
[8] Appliance adapter and gasket
[9] Combustion air blind cover and gasket
Needed Tools:
•Hole saw
• Tape measure
• Phillips screw driver
• Bottled water (as lubricant for gaskets)
•Weatherproof caulk
3Installation
3.1 Notes on Installation
NOTICE: Installer's responsibility!
▶ It is the installer's responsibility that the appliance is
installed according to the manufacturer's installation
instructions, this accessory manual, as well as
national, state, and local code.
CAUTION: Vent termination!
▶ The location and orientation of the vent termination
must follow those stated in the relevant appliance
Instruction Manual. When redirecting the flue
discharge ensure it does not create a hazard or
nuisance.
NOTICE:
▶ The concentric vent kit is approved for zero (0", 0
mm) clearance to combustibles.
NOTICE:
This vent system is ULC-S636 certified for Canada.
WARNING:
The concentric vent system is only approved in an up-
and-out configuration. No pipe extensions or
modifications are permitted.
CAUTION:
▶ Ensure the termination is installed at least 12" (300
mm) above the average snow line. If this is not
feasible, this termination can not be used.