Vent Kit Installation Manual
Table Of Contents
Spare Parts
Concentric Horizontal Vent Kit – 6 720 812 236 (2014/05)
7
3.4 Redirecting the Vent Discharge
The vent discharge can be redirected to reduce the risk of cross
contamination.
▶ Remove the screws [A] and disconnect the terminal end [B].
Fig. 12
▶ Rotate the terminal end [B] 180° so discharge faces upwards.
▶ Refit the terminal end [B] and tighten the screws [A].
Fig. 13
▶ The entire termination can now be rotated left or right 40° to
redirect the plume ( Fig. 7).
Fig. 14
▶ Use adequate weather resistant caulk to seal the penetration in the
wall and prevent moisture damage.
4 Spare Parts
CAUTION:
▶ When redirecting the flue discharge ensure it does
not create a hazard or nuisance.
Spare Parts List
Part Number Description
7 736 501 235 Concentric Up & Out Vent Kit Complete
7 736 501 234 Appliance Adapter Concentric
8 704 701 108 Adapter blue gasket
7 736 501 523 Combustion air blind cover and gasket, adapter
blue gasket
Table 3