Options & Accessories

Table Of Contents
Aquastat connection kit 7 736 505 665
26 720 887 663 (2018/05)
Fig. 2
The Tankless' set temperature should be 20 °F above the
Aquastat's set point.
Selecting the recirculation settings
Only to be used after the appliance is installed in a recirculation
application.
Fig. 3 SA - Settings
This menu provides access to several parameters.
Access to information / adjustments menu.
Display shows P4 (Information).
Press the button until the display shows SA
(Settings).
Press the button .
Display shows E.
Press buttons or to scroll through the menus.
E Exit
A1 Recirculation
A8 Startup Delay
A9 Units Set
Ab Region Selection
Press the button to select the desired menu.
A1 Recirculation
Choosing a recirculation program:
Press the button .
Press buttons or to scroll through the options.
OF OFF
rE House Recirculation
tI Tank Loading Internal NTC
tE Tank Loading External NTC
tA Tank Loading Aquastat
When the display shows tA Tank Loading Aquastat.
Press and hold the button for 3 seconds to select that
option.
Table 1
Aquastat set Temp + 20 °F = Tankless set Temp
100 °F 20 °F 120 °F
Aquastat
Temp
Tankless
set Temp
6720887700-02.1V