Options & Accessories
Table Of Contents
- Selecting the recirculation settings
- A1 Recirculation
- Sélection des paramètres de recirculation
- A1 Recirculation
- [de] Wichtige Hinweise zur Installation/Montage
- [en] Important notes on installation/assembly
- [fr] Instructions importantes pour l’installation/le montage
- [bg] Важни указания във връзка с инсталацията/ монтажа
- [cs] Důležité pokyny k instalaci/montáži
- [da] Vigtige anvisninger til installationen/monteringen
- [es] Indicaciones importantes para instalación/montaje
- [et] Olulised juhised paigaldamiseks/montaažiks
- [fi] Tärkeitä asennus- ja kokoonpano-ohjeita
- [hr] Važne upute za instalaciju/montažu
- [hu] Fontos tudnivalók az installáláshoz/szereléshez
- [it] Avvertenze importanti per l'installazione/il montaggio
- [lt] Svarbios instaliavimo ir (arba) montavimo nuorodos
- [lv] Svarīgi norādījumi par iekārtas uzstādīšanu / montāžu
- [nl] Belangrijke aanwijzingen betreffende de installatie/ montage
- [no] Viktig informasjon om installasjon/montering
- [pl] Ważne wskazówki dotyczące instalacji/montażu
- [pt] Indicações importantes relativas à instalação/montagem
- [ro] Indicaţii importante privind instalarea/montajul
- [ru] Важные указания по подключению/монтажу
- [sk] Dôležité pokyny týkajúce sa inštalácie/montáže
- [sl] Pomembni napotki za namestitev/montažo
- [sr] Važna uputstva za ugradnju i montažu
- [sv] Viktiga anvisningar för installation/montering
- [tr] Kurulum/Montaj ile ilgili önemli uyarılar
- [uk] Важливі вказівки щодо установки/монтажу
Aquastat connection kit 7 736 505 665
26 720 887 663 (2018/05)
Fig. 2
The Tankless' set temperature should be 20 °F above the
Aquastat's set point.
Selecting the recirculation settings
Only to be used after the appliance is installed in a recirculation
application.
Fig. 3 SA - Settings
This menu provides access to several parameters.
▶ Access to information / adjustments menu.
Display shows P4 (Information).
▶ Press the button until the display shows SA
(Settings).
▶ Press the button .
Display shows E.
▶ Press buttons or to scroll through the menus.
– E Exit
– A1 Recirculation
– A8 Startup Delay
– A9 Units Set
– Ab Region Selection
▶ Press the button to select the desired menu.
A1 Recirculation
Choosing a recirculation program:
▶ Press the button .
▶ Press buttons or to scroll through the options.
– OF OFF
– rE House Recirculation
– tI Tank Loading Internal NTC
– tE Tank Loading External NTC
– tA Tank Loading Aquastat
When the display shows tA Tank Loading Aquastat.
▶ Press and hold the button for 3 seconds to select that
option.
Table 1
Aquastat set Temp + 20 °F = Tankless set Temp
100 °F 20 °F 120 °F
Aquastat
Temp
Tankless
set Temp