Secure the PVC coupling to the PVC Terminal Adapter with the DuraVent Flue Pipe Clamp. Cement a short section of
PVC pipe into the PVC pipe coupling. Cement the supplied PVC exhaust terminal coupling onto the PVC pipe.
Step 8: After the venting system installation is completed, start the water heater and check all joints for leaks using a
soapy water solution. Any leaks found must be repaired. If a gasket is damaged, replacement gaskets may be obtained
from the local DuraVent supplier.
WARNING
All of the exhaust venting connections must be leak checked with a soap solution upon initial start-up of the water
heater. Any leaks must be repaired before continuing operation of the water heater.
Periodically check all venting system connections for leakage. Replace any defective venting components. Refer
to the maintenance section of the Installation and Operating Instructions for further details.
Supplied Air Intake Terminal
Cement PVC Pipe Coupling and Vent Terminal to
PVC pipe using approved solvent and cement.
Secure PVC Pipe Coupling to PVC
Adapter with Adapter Connector
Clamp.