7Bradley Corporation • 215-781 Rev. D; EN 03-310
Barrier-Free Column Shower
Installation Instructions HN-400
12-16-2003
Installation Instructions for Optional
Column Shower Shroud
NOTE: The column shower must be installed before
the shroud. The shroud clips and knock-outs in the
column cover must also be prepared. Before making
the supply connections, slide the shroud slip ring up
the vent and supply piping.
IMPORTANT: If the shroud is longer than 48"
(it has a welded seam rather than a snap
together hem) it must also be slid up the vent
and supply piping.
If the supply connections are completed prior to the
shroud installation, the supplies will have to be dis-
connected in order to slide the slip ring (and shroud if
over 48" long) over the vent and piping.
Step 3: Preparing the Column Cover
1. Remove the column cover from the top of the
shower by loosening the screw(s) that secures the
column cover retainer.
2. Carefully remove the necessary knock-outs from
the cover (see Figure 11).
3. Insert the three shroud clips into the locations
shown in Figure 11. Snap the clips in place using
a flat blade screwdriver.
4. Reassemble the cover on shower and proceed
with remainder of installation.
Step 4: Complete the Installation
1. Make sure the slip ring (and shroud if required)
is in place over the vent and supply piping.
2. Fasten the slip ring to the ceiling with five 5/16"
diameter screws (supplied by installer) (see
Figure 10 for screw location dimensions).
3. Bring the shroud seam around the vent and sup-
ply piping and slide the shroud together (0-48"
long shrouds only). Fasten hem together using
the supplied #6-32 screws.
4. With the column cover in place and the supply
connections made, lower the shroud and fasten to
the column cover with the #10-24 screws
provided (see Figures 9 and 11).
SLIP RING
S57-020A (12" LONG)
S57-141 (7" LONG)
(SLIDES INSIDE SHROUD -
FASTEN TO CEILING WITH
5/16" SCREWS SUPPLIED
BY INSTALLER)
SHROUD
(0-48" LENGTHS
HAVE HEMMED EDGE)
(54"-72" LENGTHS
HAVE WELDED SEAM)
BOTTOM OF
SLIP RING
SCREW
160-400
Figure 9