Installation Sheet
Installation
P.O. Box 309, Menomonee Falls, WI 53052-0309
TEL. 800.BRADLEY (272.3539) FAX 262.251.5817
bradleycorp.com
P20-137 Rev. A; ECM 10-15-023
© 2010 Bradley Corporation
Page 1 of 1 5/25/10
2483
Surface-Mounted
Towel Dispenser
IMPORTANT: Adequate in-wall backing must be provided by installer to fully
support the weight of the unit. Always check local codes and ordinances
prior to installation.
1. Plaster or Dry Wall Contruction: provide in-wall backing (suitable for
use with #10 x 1" screws) at the mounting slot locations.
Other Wall Surfaces: provide fiber plugs or expansion shields
(suitable for use with #10 x 1" screws supplied by installer), OR provide
1
⁄8" toggle bolts or expansion bolts. If installing where unit projects
above top of wainscot, provide aluminum channel or other filler to
prevent gap from finished wall to the back of the unit. For block walls,
use metal expansion shields.
2. Unlock the door. Secure the unit to the wall through the concealed slots
provided with the hardware appropriate for your wall construction.
IMPORTANT: For unobstructed
forward or side reach, the unit
should be installed so that the
top edge of dispensing area is
48" (1219mm) maximum above
fi nished fl oor (AFF).
Top of Unit
to Floor 6'5"
(1955mm) max.
1¾"
(45mm)
15"
(381mm)
6
5
⁄8"
(168mm)
9"
(229mm)
12
1
⁄8"
(308mm)
5
7
⁄8"
(149mm)
12¼"
(311mm)