Installation Sheet
Installation
P.O. Box 309
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
+1 262 251 6000
bradleycorp.com
P20-150 Rev. E; ECN 17-15-024
© 2017 Bradley
Page 1 of 2 7/20/2017
Install soap dispenser
The plunger assembly, flange assembly, pump
assembly and shank come pre-assembled but are
shown unassembled for clarity.
1. Provide a 1-1/4” diameter hole in the deck at the
location where the dispenser is to be installed.
2. Insert the square cut end of the supply tube through
the shank and into the bottom of the pump assembly
as shown.
3. Insert the shank with supply tube through the top of
the hole in the deck and secure with the washer and
wing nut provided.
4. Thread the soap bottle into the bottom of the shank.
Fill and prime soap dispenser
The 6334 Soap Dispenser will dispense vegetable
or coconut oil liquid soaps, synthetic detergents,
and antiseptic solutions in a liquid form. A 10–15%
concentration is recommended for vegetable or
coconut oil liquid soaps. Synthetic detergents and
antiseptic soaps require no dilution.
The soap bottle and shank are not removed when
filling the dispenser.
After filling, the soap valve must be pumped several
times to “prime” the unit, especially when it is filled for
the first time.
1. Remove the plunger assembly:
• Pull the plunger body upward and slide the
wrench onto the flats on the flange assembly.
• Rotate the wrench 1/4 turn counterclockwise to
disengage the two locating pins securing the
plunger assembly.
• Pull the plunger assembly out of the flange.
2. Pour the liquid soap through the flange opening into
the bottle up to the recommended fill level as shown.
3. Replace the plunger assembly:
• Slide the wrench onto the flats on the flange assembly.
• Insert the plunger assembly into the flange, aligning the two locating pins with the two grooves inside the
flange.
• Rotate the wrench 1/4 turn clockwise to engage the locating pins and secure the plunger assembly. Pull
the plunger upward to ensure that it is locked into place.
6334
Soap Dispenser
Plunger
Assembly
(P19-223)
Locating Pin
(qty. 2)
Flange
Assembly
(P19-224)
Wrench
(M44-075)
Pump
Assembly
(P19-225)
Shank
(P19-226)
Supply Tube
(P19-230)
Nut
(P19-228)
Soap Bottle
(P19-227)
Recommended
Soap Fill Level
Bottom end of shank
has internal threads
Washer, Rubber
(P19-229)