EXD-2N Express® Deck Lavatory System Dimensions
A
Figure 1
RIM HEIGHT
VERTICAL HEIGHT ADJUSTMENTS
“A” THROUGH “F”
FIXTURE STYLE
34” NONE STANDARD HEIGHT
34” NONE WALL HUNG
32” SUBTRACT 2” TAS, GRADES 6 THRU 8/9
31” SUBTRACT 3” JUVENILE HEIGHT
30” SUBTRACT 4” TAS, PRE-K THROUGH 5/6
CODE DESCRIPTION QTY.
“A” 3/8” BOWL WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 LBS. 2
“B” 3/8” MAIN FRAME WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 LBS. 6
“C” 3/8” BASE FRAME WALL ANCHORS, STANDARD FRAME OPTION ONLY. 2
“D” 1/2” NOMINAL COPPER TUBING HOT/COLD SUPPLIES, STUB OUT 2” FROM WALL 2
“E” 1-1/2” NPT DRAIN, STUB OUT 2” FROM WALL 1
“F” 110V GFCI PROTECTED ELECTRIC OUTLET (FOR OPTIONAL ELECTRONIC FAUCETS) 1
“G” #10 WALL ANCHORS/FASTENERS FOR OPTIONAL NAVIGATOR
®
VALVE MOUNTING 2
CHART 1
CHART 2
23½"
(597mm)
23½"
(597mm)
13¼"
(337mm)
9
3
8"
(238mm)
9
3
8"
(238mm)
Option#1
A
3"
(76mm)
4"
(102mm)
BB
D D
E
F
B B
G
G
C C
Hot Supply
Option#2**
Cold or
Tempered
Supply Option
4"
(102mm)
1
3
8"
(35mm)
32"
(813mm)
25¾"
(654mm)
20"
(508mm)
Floor
21"
(533mm)
19"
(483mm)
2"(51mm)
13"
(330mm)
3½"
(89mm)
15"
(381mm)
22"
(559mm)
28¾"
(730mm)
* Option 1 - Recommended 240V/208V or 277V
Electrical Box Location (4"L x 4"W x 8"H)
or
**Option 2 - Recommended 240V/208V or 277V
Electrical Box Location (4"L x 4"W x 4"H)