Installation manual
Installation  SS-2N/AST/STD, SS-2N/AST/WH
Bradley Corporation • 215-1498 Rev. F; ECM 11-08-011  10/24/11  13
Tempered Line Adapter Option 
Part no. S39-804
(replaces S59-4000 if tempered line 
is used)
Strainer 
(173-028)
Problem Cause Solution
External 
leaks.
Damaged cartridge or O-rings. Replacecartridgewithpartnumber269-1927
Improper water 
temperature or 
temperature 
fluctuation.
Hot water supply is not 10° above desired set point. Increase hot water supply temperature
Valve temperature is not properly set. Adjustthetemperatureasshownonpage10,step8.
Limited water 
flow.
Dirt and debris have built up in the valve or strainer. 1.Checktomakesurebothhotandcoldsuppliesare
connected to the Navigator mixing valve and that they 
have water flow.
2. Remove cover and U-clip. Remove the cartridge and 
clean the strainer. It is not required to grease cartridge, 
however if desired, use silicone grease only. Do not use 
greaseoncheckvalves.
Parts List
Item Part No. Description
Quantity
S59-4000 S59-4000A S59-4000BY
1 160-463 Cap Screw 1 1 1
2 107-582 Cover 1 1 1
3 269-1927 Thermostatic Cartridge 1 1 1
4 198-014 CheckValve* 2 2 2
5 132-051 RetainingRing* 2 2 2
6 118-319 Valve Body 1 1 1
7 146-079 U-Clip 1 1 1
*IncludedwithPrepackS65-326
1
2
3
4
5
4
5
7
6
Thermostatic Mixing Valve Troubleshooting
Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions:
• Ifstopvalvesareused,makesurethattheyarefullyopen.
• Makesurethatthehotandcoldinletpipesareconnectedproperly,andthattherearenocross-connectionsor
leaking stop valves.
• Checkthehotwaterheateroutputtomakesurethatitisatleast10°Fabovethesettemperature.
Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the valves after inspection and 
repair is complete.