Installation Sheet

17
Installation Powder Coated & Stainless Steel Restroom Partitions, Floor-Mounted with Overhead Brace Series 400
Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007 3/21/2018
7
Headrail
Make sure the pilasters are plumb and that the pilaster has been secured to the mounting hardware. Leave the appropriate
door opening between the pilasters as shown on your submittal drawing.
Completed Headrail Assembly
The illustrations on this page show mounting hardware and fasteners for a generic application. Refer to your submittals
to determine your actual headrail configurations.
Some headrail sections may need to be cut to an appropriate size. Refer to your submittals for general headrail placement.
Headrail configurations that come to an intersection should meet over pilaster (see completed headrail assembly view below).
Wall
Place headrail over the top of each pilaster
located at the wall and slide it tight against the
side wall. Mark the outline of the headrail on the
wall and remove the headrail.
A
Place the headrail bracket on
the outline marked on the wall
and mark the locations of the
mounting holes. Remove bracket
and drill (2) Ø5/16" holes a
minimum of 2" [51 mm] deep.
Prior to securing to the wall,
enlarge the (2) back mounting
holes of the bracket to Ø1/4".
Secure the bracket to the wall
with the #14 x 2" screws and
plastic anchors provided.
B
Place headrail over the top of the pilasters and
slide it tight into the mounting bracket. Use the
mounting bracket as a template and drill a Ø7/32"
hole through the headrail. Secure the headrail to
the mounting bracket with the #10 x 5/8" screws
provided.
C
Make sure the pilaster is plumb
and that the spacing between
the pilasters for the doors is the
correct dimension. On the back
of each pilaster (starting with the
first pilaster), drill a Ø7/32" hole
through one face of the headrail
only.
Using this hole as a template,
drill a Ø9/64" pilot hole into the
pilaster, 5/8" (16mm) deep.
Secure the headrail to the
back of each pilaster with the
#10 x 5/8" screws provided.
D
For open end applications, cut the headrail to the appropriate length (if
required). Attach the bracket to the wall at the correct height (see step B).
Attach another bracket to a pilaster with #10 x 5/8" screws at the correct height
(see view below). The headrail should be level with any adjacent headrail
and should be located directly over the panel. Position each headrail onto the
brackets and secure with required fasteners (see step C). Using a rubber mallet,
install the headrail end cap.
E