Installation MG-2/BIR3 Express® Lavatory System - MG Series with Battery Infrared Control Table of Contents Pre-Installation Information . . . . . . . . . . . . . . . . . . . . . . 2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . 5-11 Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . 12 Assembly of Components . . . . . . . . . . . . . . . . . . . .
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Pre-Installation Information Barrier-free and ADA compliant - standard height mounting The MG-2/BIR3 Express® Lavatory System with Battery Infrared Control must have a rim height no higher than 34" above finished floor to be compliant with Americans with Disabilities Act (ADA).
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation MG-2/BIR3 Express® Lavatory System Dimensions 54" (1372) (mm) 42" (1067) 15" (381) 15" (381) (mm) 27" (686) 47" (1194) 22" (559) (mm) 9-1/2" (241) 21-1/2" (546) *39" (991) *33-1/2" (851) *29-1/2" (749) *17-1/2" (445) *Subtract 4" from vertical dimensions for compliance with ADA guidelines for children’s use. Bradley • 215-1510 Rev.
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Dimensions continued . . . (mm) TAS Juvenile Height Grades Pre-K thru 5 or 6 35½" (902) 30" (762) 26" (660) 14" (356) FLOOR (mm) TAS Juvenile Height Grades 6 thru 8 or 9 4 4/9/2014 37½" (952) 32" (813) 28" (711) 16" (406) FLOOR Bradley • 215-1510 Rev.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Installation Instructions Step 1: Rough in supplies and optional hot water heater NOTE: See Figure 1 (below), 1a, 1b (for TAS on page 6) and Figure 2 (on page 7) when roughing in the MG-2/BIR3 Express®. IMPORTANT: Flush the supply lines before making connections. Debris in supply lines will cause the valves to malfunction.
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 TAS - Texas Accessibility Standards: Juvenile Height (grades Pre-K thru 5 or 6) Installation CENTERLINE OF FIXTURE 25½" (648) APPROX. DIMENSION 25½" (648) APPROX.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Installation Instructions continued . . . Step 2: Rough in wall anchors 1. Install six ³⁄₈" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations marked (ref. location “B" shown in Figure 1, 1a or 1b on pages 5-6). NOTE: The dimensions for the wall anchors at location “A" are for reference only. 2.
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Installation Instructions continued . . . Step 3: Mount frame to wall 1. Loosen, but do not remove the bottom three access panel screws. 2. Remove the two top access panel screws and washers securing the access panel to the frame and remove the access panel (see Figure 3). 3. Position the frame with Terreon® End Caps attached, against the wall, ensuring that it is level.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Installation Instructions continued . . . Step 4: Install bowl assembly IMPORTANT: See Figure 4 below when installing the bowl assembly. If the fixture has soap option, refer to the soap system installation manual 215-1585 before installing the bowl assembly. 1. With someone to assist you, place the bowl assembly squarely onto the frame being careful not to pinch tubing between bowl and frame. 2.
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Installation Instructions continued . . . Step 5: Connecting supply 1. Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve bracket up until the larger cutout in the frame’s slot aligns with the screw head (see Figure 5b). Then lift up to remove the valve bracket from the frame. 2.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Installation Instructions continued . . . Step 7: Connecting electrical and supply tubing WARNING: The MG-2/BIR3 must be connected to the 6 VDC battery. Connection to 110 VAC may cause personal injury and/or damage to electronics. Connection of leads other than shown may cause permanent sensor damage.
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Installation Instructions continued . . . Step 8: Adjust the temperature This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110°F (43°C) may cause scalding. 1. Check the temperature when approximately 1.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Cleaning and Maintenance Instructions IMPORTANT: Strong alkaline or acid-based chemicals and cleansers should not be used to clean the MG-2/BIR3 Express®. If these chemicals come in contact with the Terreon® surface, wipe off the surface immediately and flush with soapy water. Avoid unnecessary or prolonged contact with hot pans and objects.
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Assembly of Components SPRAYHEAD BODY (PART NUMBER VARIES WITH COLOR OF UNIT. CONTACT YOUR LOCAL BRADLEY REP. FOR ASSISTANCE). BOWL (PART NUMBER VARIES WITH COLOR OF UNIT. CONTACT YOUR LOCAL BRADLEY REP. FOR ASSISTANCE). END CAP (LEFT) (PART NUMBER VARIES WITH COLOR OF UNIT. CONTACT YOUR LOCAL BRADLEY REP. FOR ASSISTANCE). SPRAYHEAD MOUNTING BOLTS (3) END CAP (RIGHT) (PART NUMBER VARIES WITH COLOR OF UNIT.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Assembly of Components continued . . . Sensor assembly and solenoid valve access • To access solenoids: Using a ⁵⁄₃₂" Allen socket wrench, loosen, but do not remove the bottom three access panel screws. Remove the two top access panel screws and washers securing the panel to the frame and remove the access panel (see Figure 3 on page 8). Solenoids are located on left side of frame (see Figure 9).
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Assembly of Components continued . . . SENSOR EYES 30" (251-019A) 60" (251-019B) INFRARED WINDOW 269-1241 SPRAYHEAD BODY NUT 110-115 CONNECTOR 1/4" TUBE 145-089 ACCESS PLATE 150-201 HOUSING, FLOW CONTROL S05-142A SCREW ALLEN SOCKET #10-24 160-138 Figure 11a WINDOW PURPLE EYE Figure 11b 16 4/9/2014 Bradley • 215-1510 Rev.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Troubleshooting BIR3 Components CAUTION: Turn off water supplies to unit before troubleshooting. Problem: An individual operating station drips and fails to shut off. Cause: There is debris trapped between the diaphragm and the valve seat. Solution: Remove debris between diaphragm and the valve seat. Disconnect the plug from the battery to the circuit board of the problem valve.
Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Troubleshooting – Stop Valve Problem Cause Solution Water just dribbles or does not flow from sprayhead Water supply malfunctioning 1. C lose the stops and check the valves that supply water to the lavatory system. Water sprayhead delivers all hot or cold water Water supply or mixing valve malfunctioning 2. I nspect the stop valves for proper installation. 1.
Express® MG Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Thermostatic Mixing Valve Troubleshooting Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions: • If stop valves are used, make sure that they are fully open. • Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or leaking stop valves.