Installation manual
Express
®
Lavatory System - MG-Series with TouchTime
®
Control
MG-2/TT Installation
2 4/9/2014 Bradley • 215-1480 Rev. G; ECN 13-08-025
Pre-Installation Information
Barrier-free and ADA compliant - standard height mounting
The MG-2/TT Express
®
Lavatory System must have a rim height no higher than 34" above finished floor to be
compliant with Americans with Disabilities Act (ADA). When mounted at 34" rim height, the MG-2/TT Express
®
Lavatory System meets ADA, ANSI and UFAS requirements for barrier-free clearances, reaches and controls.
Always check local codes and ordinances for compliance.
Barrier-free and ADA compliant - juvenile height mounting
The MG-2/TT Express
®
Lavatory System must have a rim height no higher than 30" above finished floor to
be compliant with Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities:
Building Elements Designed for Children’s Use; Final Rule.
Texas Accessibility Standards compliant:
The MG-2/TT Express
®
Lavatory System meets Texas Accessibility standards (TAS) for barrier-free
clearances, reaches and controls. Always check local codes and ordinances for compliance.
TouchTime
®
switch and solenoid
Each sprayhead is controlled by a TouchTime
®
switch, enabling each user to activate a single flow of water.
Each valve uses less than half the maximum of hot water allowed by the ANSI/ASHRAE/IESNA 90.1-1989
Standard.
Supplies required for installation:
• (8)³⁄₈" wall anchors, bolts and washers to mount frame and bowl to wall
(minimum pull-out rating of 1,000 lbs.)
• ½"Nominalcoppertubingforhotandcoldsuppliesand1½"NPTdrainpiping
• 110voltelectricaloutletfor110/24VACplug-intransformer(supplied)
• 240/208-voltor277-voltelectricaloutletforoptionalelectrictanklesswaterheater