Installation Guide
4 7/6/2010 Bradley Corporation • 215-1582 Rev. G; EN 10-02-011
3
Connect the Valve Control Module
A
PLACE RUBBER
WASHER INTO WHITE
TOP NUT FITTING.
B
HAND TIGHTEN VALVE
CONTROL MODULE TO
FAUCET SHANK.
2
Attach Activation Hardware to Faucet Shank
3-in-1 Washer
BRASS MOUNTING NUT
SENSOR WIRE CONNECTION WASHER
BRASS MOUNTING NUT
A
ATTACH GROUNDING
HARDWARE TO SHANK
IN THE ORDER SHOWN.
B
ATTACH ACTIVATION
HARDWARE TO SHANK
IN THE ORDER SHOWN.
S53-315 Installation
Tab on 3-in-1 Washer must be
positioned 180 degrees opposite
tab on Sensor Connection Washer.