Installation Guide

Installation S53-315
5Bradley Corporation • 215-1582 Rev. G; EN 10-02-011 7/6/2010
5
Connect Sink Ground Wire
IMPORTANT
For applications without a Trim Plate,
cut off the Ring Terminal Side and
discard. The remaining portion of wire
can be taped to the Sink Ground Wire
using Electric Tape. For applications
using Trim Plate, refer to Step C.
SINK GROUNDING TAB WASHER
U-TAB CONNECTION
RING TERMINAL SIDE
SINK GROUND WIRE
A
CONNECT SINK/DRAIN
GROUND WIRE TO
SINK GROUNDING
TAB WASHER.
C
PLACE RING TERMINAL SIDE
ON ONE OF THE THREADED
STUDS AND FASTEN WITH
LOCK WASHER AND NUT.
B
CONNECT THIS END OF SINK
GROUND WIRE TO ONE TAB ON
U-TAB CONNECTION.
D
ATTACH DRAIN
WIRE CLAMP TO
SINK DRAIN
Connect Sensor Wire
BLACK SENSOR WIRE
SENSOR WIRE CONNECTION WASHER
A
CONNECT SENSOR WIRE TO
SENSOR WIRE CONNECTION
WASHER.
4