Installation Guide

S53-315 Installation
6 7/6/2010 Bradley Corporation • 215-1582 Rev. G; EN 10-02-011
Install and Connect Battery Pack
IMPORTANT
For Installations using Optional AC Power Source,
connect Power Source as shown in Step C.
VALVE CONTROL
MODULE POWER
CONNECTION
BATTERY BOX CONNECTOR
(OR AC POWER CONNECTOR)
A
REMOVE BATTERY
BOX COVER BY
UNSCREWING (2)
PHILLIPS SCREWS.
C
CONNECT BATTERY BOX CONNECTOR (OR AC
POWER CONNECTOR) TO VALVE CONTROL
MODULE POWER CONNECTION.
B
SECURE BATTERY
COMPARTMENT
TO WALL USING
WALL ANCHORS
OR DOUBLE-SIDED
TAPE. INSERT (4)
D-CELL ALKALINE
BATTERIES AND
REPLACE COVER.
7
6
Install Earth Ground Assembly
A
CONNECT EARTH
GROUNDING CLAMP TO
COLD WATER SUPPLY
BETWEEN SHUT OFF
VALVE AND WALL PLATE.
B
CONNECT EARTH
GROUNDING CONNECTOR
TO REMAINING TERMINAL
ON U-TAB CONNECTOR
IMPORTANT
Be sure to attach directly to the
Copper Pipe and not to the Shut
Off Valve.