Specification Sheet

S53-315
Aerada
1200 Series CS Faucet
© 2018 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000
bradleycorp.com
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to
local and national codes is the responsibility of the installer.
Page 1 of 1 6/13/2018
This information is subject to change without notice.
Bradley_Faucets_S53-315
• ADA Compliant Hands-Free Activation
• c/UPC Certified
• Capacitive Sensing Omni-Directional Detection Zone
• 6 VDC Control Powered by (4) ‘D’-Cell Alkaline Batteries (included)
• Optional 100-120 VAC Plug-in Adapter
• Optional 100-120 VAC 6-Unit Plug-In Adapter
• Includes 4" Anti-Rotational Trimplate
Specifications
Component Operation
6VDC battery-powered control powered by (4) "D"-cell alkaline batteries
(included). Average battery life: 500,000 activations. Optional 100-120 VAC
plug-in adapters are available for both single and multi-faucet applications.
Flow Control/Rate
Operating water pressure range is 20-80 psi. Flow regulator keeps flow rate
constant at all pressures. The flow is laminar and delivers a maximum of 0.16 GPC.
Body
Chrome plated solid brass body. Centershank or 4" centerset mounting (with
included trimplate). 8" trimplate available separately.
Standard Equipment
The Aerada
1200 Series CS faucet creates on omni-directional detection zone
utilizing capacitive sensing technology. The capacitive sensing field triggers
faucet activation only when a significant change in the capacitive field occurs.
Only human presence will create a significant change in the capacitive field. As
such, inanimate objects will not trigger faucet activation. The faucet is unaffected
by varying skin tones, other infrared presence and soap scum build-up.
Valve
The electronically activated motor driven valve provides reliable performance
since there are few moving parts. Valve includes an in-line filter to trap debris
and is unaffected by most chemicals and minerals found in municipal water
supplies. Valve features a factory-set maximum water run-on duration of
15 seconds. Valve control module features a manual override control for
applications requiring periodic flushing of the water lines. The valve and
electronics are enclosed in a water-resistant housing mounted below the fixture.
Sample Specification
Hands-free capacitive sensing faucet shall be Bradley Aerada 1200 Series CS faucet
(S53-315). Capacitive sensing technology creates an omni-directional detection
zone enabling faucet activation to occur regardless of angle of approach and requires
no infrared sensors. The faucet will only activate when human presence enters
the detection zone; inanimate objects will not cause faucet activation. The omni-
directional detection zone is automatically calibrated when power is initially supplied
to the faucet. The 6 VDC faucet is powered by (4) 'D'-cell alkaline batteries (included)
concealed inside a remotely located battery box. The electronically activated motor
control valve is enclosed in a water-resistant housing mounted beneath the fixture.
Valve control module to have maximum water run on duration of 15 seconds
providing increased water conservation. Faucet shall feature chrome-plated solid
brass spout with centershank, or 4" centerset mounting with included anti-rotational
trimplate. Faucet shall be c/UPC approved.
Models
Faucet with Trimplate:
S53-315 Aerada 1200 Series CS Faucet
Optional Selections
Trimplate:
159-428 8" Trimplate and Hardware
Plug-In Adapter:
153-443 100-120 VAC Plug-In Adapter (Single Faucet)
153-444 100-120 VAC 6-Unit Adapter (2-6 Faucets)
269-1841 Wire for 6-Unit Adapter (1 per Faucet)
Water Supply:
S45-2760 TMA Navigator
®
Thermostatic Mixing Valve Pre-Pack with
Flexible Hoses and Stops
S45-2731 TL Flexible Hose and Stop Pre-Pack
Drain Assembly:
269-1839 D-ASSY, Drain, Strainer and Tailpiece
6-1/2"
(165)
3-3/4"
(95)
2" (51)
2-1/8"
(54)
7"
(178)
3-1/8"
(79)
5-5/8"
(143)
1-5/8"
(41)
5-1/8"
(169)
5-1/2"
(140)
4"
(102)
2-3/8"
(60)
Valve housing
can be rotated
to any position
(mm)
Certified to
NSF/ANSI 372
Standard product selections contained within this document are third
party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content
requirement. Any product configured with custom options will be
COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content
requirement.