Installation Guide

12
Aerada 1000/1100 Series Installation
9/1/2016
Bradley • 215-1628 Rev. C; ECN 16-02-002
180°
95%
85%
7
Install shut-off screw.
8
Install mixer handle (for faucets with
external mixer only).
Cleaning or Replacing Inlet Filter
1
Close supply valves.
2
Disconnected braided hoses and clean or replace
filter. For a new filter, see Replacement Parts
section.
3
Connect braided hose with filter to supply valve.
Cold water = White Label Hot Water = No Label
Adjusting Hot Water Limiter
(External Mixer)
The proportion of hot water can be switched from
approximately 85% to 95% (or reverse) depending
upon inlet water pressures and temperatures. The
default setting is 85%.
CAUTION Hot water may burn skin. Hold
hand carefully under water and
remove quickly.
1
Remove mixer handle.
2
Carefully pull out hot water limiter from handle
(using pliers) and reverse by 180°.
Settings of hot water limiter (view from
placement in mixer handle)
3
Mount mixer handle. The proportion of hot
water is now changed.