Installation Guide

3
Installation Aerada 1000/1100 Series
Bradley • 215-1628 Rev. C; ECN 16-02-002 9/1/2016
Installation
This faucet comes with all the components needed for
installation,however, some tools and supplies are not
included.
Basin Wrench
Adjustable Wrench
Adjustable Locking Pliers
Plumber´s Putty
Hex Key (supplied)
Outlet Key (supplied)
Do not use pipe dope on faucet and supply
connections. Possible solenoid contamination could
occur and will void any warranty.
Mounting of Lavatory and Gooseneck
Faucet
Before mounting faucet, be sure:
Supply Valve is installed
Water supply lines are flushed properly
For AC faucets, power outlet is installed
It is not necessary to unscrew the connection
between braided hose and housing to install the
product
Do not remove protective covering from sensor until
starting up faucet operation.
Do not tighten locknut before step 4 is completed.
1
Mount cover plate, if required. Plumber's putty is
recommended to seal the cover plate to the sink.
Security pin must be located on the left side.
2
Mount gasket and put faucet into sink.
3
Mount bracket from underneath. Place hoses
through large opening and mounting rod
through small opening. Make sure flange sits
securely against surface.
4
Place nut onto mounting rod and tighten with
wrench.
5
If faucet was installed with cover plate, secure
with basin washer, flat washer and locknut.
6
Install aerator and tighten with aerator key
(supplied).
7
For Gooseneck faucets, tighten spout with
wrench.
8
Connect braided hose with filter to supply valve.
Cold water > white label Hot water > no label
For AC faucets, please refer to the plugin or
hardwired transformer installation instructions.
9
Connect to power supply.