Installation Guide

5
Installation Aerada 1000/1100 Series
Bradley • 215-1628 Rev. C; ECN 16-02-002 9/1/2016
a
c
b
Enabling "Manual Setting Mode"
A battery model is shown in the following example. These
instructions apply to all models. After 30 minutes, the
"Manual Setting" mode will be disabled automatically and
all settings will be saved.
Before enabling mode, be sure:
Water supply valve is open.
Battery is full (LED does not blink) for DC faucets.
AC power is on for AC faucets.
1
Remove shut-off screw.
2
Remove mixer handle (only for faucets with
external mixer).
3
Remove housing vertically.
4
Remove battery from battery holder.
5
The following procedure (a, b, c) must be
done three (3) times in a row.
a - Re-insert battery
b - LED lights up
c - Remove battery immediately after LED
switches off.
6
Insert battery.
7
Mount housing vertically.
8
Mount shut-off screw.