Installation Guide

6
Aerada 1000/1100 Series Installation
9/1/2016
Bradley • 215-1628 Rev. C; ECN 16-02-002
9
Mount mixer handle (only for faucets with
external mixer).
Setting Faucet Mode
Setting the cleaning mode will make the faucet
inactive for 90 seconds.
1
Enable "Manual Setting" Mode (see "Manual
Setting Mode" on page 5).
2
Fully cover sensor with hand until water flow
stops. This takes 5 seconds.
3
Remove hand. The Cleaning Mode is now
active. For the next 90 seconds, the faucet will
be inactive.
Setting Normal Mode
Setting the normal mode will allow the faucet to
activate only when it senses a hand presence.
1
Enable "Manual Setting" Mode (see "Manual
Setting Mode" on page 5).
2
Fully cover sensor with hand. Water flow stops
after 5 seconds. Continue to hold on for one (1)
additional water pulse.
3
Remove hand. Normal Mode is now activated.
Setting Metering Mode (10 seconds)
Setting the metering mode will allow the faucet to activate
for a full 10 seconds after it senses a hand presence.
1
Enable "Manual Setting" Mode (see "Manual
Setting Mode" on page 5).
2
Fully cover sensor with hand. Water flow stops
after 5 seconds. Continue to hold on for another
two (2) additional water pulses.
3
Remove hand. Metering Mode is now activated
for 10 seconds.