Installation Guide

9
Installation Aerada 1000/1100 Series
Bradley • 215-1628 Rev. C; ECN 16-02-002 9/1/2016
Problem Possible Cause Solution
No water flow Supply valves are closed Open supply valves
Aerator is blocked or dirty Clean or replace aerator (See "Care and Maintenance")
Inlet water line filter is dirty or
blocked
Clean or replace filter (See "Care and Maintenance")
Braided hose is kinked Eliminate braided hose kink
No external water pressure Check water pressure/Provide water pressure
Battery is drained (DC
faucets only)
Replace battery (See "Care and Maintenance")
Battery contacts are corroded
(DC faucets only)
Clean contacts or replace battery (See "Care and Maintenance")
Reverse battery insertion Insert battery correctly
Connector between
transformer and power
adapter unplugged (AC
faucets only)
Plug connector
Power adapter contacts are
corroded (AC faucets only)
Clean contacts
Connecting cable is kinked or
broken (AC faucets only)
Replace defective parts (See "Replacement Parts")
No external power supply
(AC faucets only)
Check external power supply/Provide power supply
Shut-off screw is missing or
defective
Replace shut-off screw (See "Replacement Parts")
Solenoid valve inoperable Replace solenoid valve (See "Replacement Parts")
Faucet is in cleaning mode Wait for cleaning mode to end (appr. 90 seconds)
Electronics module
inoperable
Contact Bradley technical service or replace power adapter (See
“Replacement Parts”)
Power adapter defective (AC
faucets only)
Contact Bradley technical service or replace power adapter (See
“Replacement Parts”)
Sensor distance is not
adjusted properly
Reset sensor monitoring range
Remove and re-install shut-off screw. Do not disturb sensor scanning
procedure (wait until water flow stops and LED switches off)
Infrared window scratched
or dirty
Clean window with smooth cloth
Troubleshooting