Installation manual
SS-3N/IR/STD, SS-3N/IR/WH Installation
6 10/24/11 Bradley Corporation • 215-1493 Rev. G; ECM 11-08-011
FLOOR
A, F
A, F
B
B
B
B
B
B
C
C
D1 D2
E
38-1/2"
(978mm)
24-3/8"
(619mm)
8"
(203mm)
13"
(330mm)
C
L
2-3/4"
70mm)
4"
(102mm)
24-3/8"
(619mm)
38-1/2"
(978mm)
32"
(813mm)
28-3/4"
(720mm)
15"
(381mm)
5-5/8"
(143mm)
27-1/2" (699mm)
18" (457mm)
24"
(610mm)
23"
(584mm)
34"
(864mm)
RIM
HEIGHT
SEE
CHART
BELOW
3-1/2
(89mm)
G
H
J
1
Rough-Ins
CODE DESCRIPTION QTY.
A
³⁄₈" Wall Anchors with a minimum pull-out force of 1,000 lbs. for Bowl
2
B
³⁄₈" Wall Anchors with a minimum pull-out force of 1,000 lbs. for Mainframe
6
C
³⁄₈" Wall Anchors for Base Frame, Standard Frame option only, minimum pull-out force not required
2
D1 ½" nominal copper tubing for Cold Supply, stub-out 2" from wall 1
D2 ½" nominal copper tubing for Hot or Tempered Supply, stub-out 2" from wall 1
E 1½" NPT Drain, stub-out 2" from wall 2
F
On the bowl back, measure the distance between the ¾" bowl mounting holes. Divide this measurement
in half. Measure and mark this dimension on the wall to the left and the right of the centerline. Install two
³⁄₈" wall anchors with a minimum pull-out rating of 1,000 lbs (supplied by installer) at locations marked.
2
G
Water Heater Option #1: Rough-in appropriate electrical supply per local code (recommended location for
240/208v or 277v electrical box [4" long x 4" wide x 8" high] shown)
1
H
Water Heater Option #2: Rough-in appropriate electrical supply per local code (recommended location for
240/208v or 277v electrical box [4" long x 4" wide x 4" high] shown)
1
J 110v GFI Protected Electrical Outlet 1
RIM HEIGHT
VERTICAL HEIGHT ADJUSTMENTS FOR CODES
A–E, H, C and W
FIXTURE STYLE
34" None Standard Height
34" None Wall-Hung
32" Subtract 2" TAS, Grades 6 through 8 or 9
31" Subtract 3" Juvenile Height
30" Subtract 4" TAS, Pre-K through Grades 5 or 6