Installation TDB3104 Terreon 54" Semi-Circular Deep Bowl Washfountain with Air Metering Valve ® TDB3104 with Push Button Air Valve Available in standard height, juvenile height, and TAS height. WF3204 Terreon Extra Height 54" Semi-Circular Classic Washfountain with 9" Deep Bowl and Air Metering Valve ® Table of Contents WF3204 with Push Button Air Valve Pre-Installation Information . . . . . . . . . . . . . . . . . . . . . . . . 2 Semi-Circular Washfountain Dimensions . . . . . . . . . . .
TDB3104, WF3204 Installation IMPORTANT! Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Installation Packing List IS TH SIDE UP • • • • Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts.
TDB3104, WF3204 Installation Semi-Circular Washfountain Dimensions Model TDB3104 Model TDB3104 (Juvenile Height) 54" Semi-circular - side view 54" Semi-circular - side view 32-1/4" (819) 5-1/4" (133) 32-1/4" (819) 5-1/4" (133) Adjust to Towel Dispenser Mounting Holes Adjust to Towel Dispenser Mounting Holes 6" (152) 6" (152) 64" (1626) w/ Soap 55-1/2" (1410) w/o Soap 22-3/4" (577) 55-3/4" (1416) 47-1/4" (1200) 43-3/4" (1111) 27" 34" (686) (864) 40" (1016) 22-3/4" (577) 42-5/8"* (1084) 34"* (
TDB3104, WF3204 Installation Semi-Circular Washfountain Dimensions Model WF3204 54" Semi-circular - side view 32-1/4" (819) 22-3/4" (577) 5-1/4" (133) Adjust to Towel Dispenser Mounting Holes 6" (152) 64" (1626) w/ soap 55-1/2" (1410) w/o soap 55-3/4" (1416) 47-1/4" (1200) 43-3/4" (1111) 41" (1041) 34" (864) 23-1/2" (597) 15" (381) Model WF3204 is not ADA compliant 4 1/10/2013 Bradley • 215-1470 Rev.
TDB3104, WF3204 Installation (mm) Rough-In Specifications Type A Drain - Supplies from below or through wall - Vent from below or through wall off-drain 1/2" Nominal Copper Tubing Supplies Through Wall 1/2" Nominal Copper Tubing for Cold Supply Through Floor (Optional), Stub Up 2-1/2" (64) Above Floor 2" NPT Drain Through Floor, Stub up 3" (76) Above Floor 13" R Top Access 7-5/8" (194) 4" (102) 54" (1372) Bowl Wall 7-5/8" (194) 5-1/4" (133) 7-3/8" R Bottom Access 3-1/4" (83) 1/2" Nominal Copper
TDB3104, WF3204 Installation Rough-In Specifications Type H Drain - Supplies from below or through wall - Vented through ceiling off trap inside pedestal (mm) 1/2" Nominal Copper Tubing Supplies Through Wall 13" R Top Access 7-3/8" R Bottom Access 7-5/8" Cold (194) 1-1/2" NPT Vent to Ceiling 1/2" Nominal Copper Tubing Supplies Through Floor (Optional), Stub Up 2-1/2" (64) Above Floor 4" (102) 7-5/8" Hot (194) Wall 54" (1372) Bowl 5-1/4" (133) 2" NPT Drain, Stub Up 3" (76) Above Floor 3-1/4" (83
TDB3104, WF3204 Installation 1 Installing the Drain A Rough in supply and drain piping as required for your installation. B Assemble the drain to the dimension for the bowl you are installing. All piping shown in dotted lines to be supplied by installer.
TDB3104, WF3204 2 A Installation Bowl/Pedestal Mounting and Assembly Position the pedestal at desired location and mark the position of the (2) pedestal wall mounting locations and (2) pedestal floor mounting locations. CAUTION! Bowl surface is very smooth. Approximate weight of bowl is 146 pounds (model TDB3104), 136 pounds (model WF3204) or 101 pounds (model TDB3104/JUV). Handle with Care! Top View TAS OPTION: Place TAS spacer on floor over the mounting holes. Place pedestal on top of the spacer.
TDB3104, WF3204 Installation 4 Connect Supply Tubing to Sprayhead Male Tube Connector Install 3/8" supply tubing in the sprayhead using the male connector. • Using a sharp razor, cut tubing squarely and remove any burrs. DO NOT pinch or crush end of tubing. A • Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated. Tighten nut to secure tube to fitting (make sure nut is securely tightened). Nut Tubing Sprayhead • If connector leaks, reseat tubing.
TDB3104, WF3204 5a Installation Air Metering Valve Assembly for A Drain and O Drain Units without Tie Pipe Option A Install hemmed end (not sharp end) of support tube with gasket onto bowl. B Place sprayhead with 3/8" tubing onto support tube. Run the tubing down through the support tube and connect to valve tube connector. Make sure the spray holes point away from the wall. C Place the upper tie bar (notched at both corners of each end) on top of sprayhead parallel to wall.
TDB3104, WF3204 Installation 5a D Air Metering Valve Assembly for A Drain and O Drain Units without Tie Pipe Option continued... Place the actuator module assembly on top of sprayhead. Rotate until actuator module locks in with tie bar. Drop 1/8" diameter tube down to valve assembly and connect to the air valve. Make sure air valve push button is facing away from the wall.
TDB3104, WF3204 5b Installation Air Metering Valve Assembly for B Drain and H Drain Units with Tie Pipe Option A Install hemmed end (not sharp end) of support tube with gasket onto bowl. B Place sprayhead with 3/8" tubing onto support tube. Run the tubing down through the support tube and connect to valve tube connector. Make sure the spray holes point away from the wall. C Insert the 1-1/2" vent pipe (supplied by installer) down through the support tube and thread into vented trap.
TDB3104, WF3204 Installation 5b Air Metering Valve Assembly for B Drain and H Drain Units with Tie Pipe Option continued... D Place the actuator module assembly on top of the sprayhead. Rotate until actuator module locks in with tie bar. Drop 1/8" diameter tube down to the valve assembly and connect to the air valve. Make sure air valve push button is facing away from wall. Skip to step F for units without soap.
TDB3104, WF3204 6 Installation Valve and tubing connections Valve Bracket 3/8" Tube from Sprayhead Flush supply lines before making connections. Do not apply pipe sealant to compression fittings. A 14 Attach hot and cold flexible supply lines to mixing valve assembly, two places. Make sure the hot supply is connected to the hot inlet on the valve (marked with the letter "H") and the cold supply is connected to the cold inlet on the valve (marked with the letter "C").
TDB3104, WF3204 Installation 7 Adjust the Temperature This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110°F (43°C) may cause scalding. A B Loosen Cap Screw about 1/4" (4-6 turns) and lift up cover (do not remove). Using cover, turn cartridge gently until desired water temperature is reached. Do not turn past stops as this may damage unit. Push cover down and tighten screw.
TDB3104, WF3204 Installation Cleaning and maintenance instructions for Terreon ® Material Description: Terreon is an NAHB Certified densified solid surface material composed of polyester resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. ® Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household cleaner such as Formula 409 or Windex .
TDB3104, WF3204 Installation Cleaning and maintenance instructions for stainless steel Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly under corrosive conditions, is essential. Always start with the simplest solution and work your way toward the more complicated. Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia.
TDB3104, WF3204 Installation Soap Valve — Liquid — S09-007S Parts List 3 Attaching Parts S09-007S Item Part No. Description 1 118-025 Valve Body 1 2 110-007 Packing Nut 1 3 135-001L Spring 1 4 125-001BU Washer 1 5 119-028 Plunger 1 * 161-014 Nut 1 * 124-001D Washer 2 * 142-002AH Washer - Stainless Steel 1 1 Qty 4 5 2 * Not Illustrated This valve delivers a measured amount of soap with each upward stroke.
TDB3104, WF3204 Installation Soap Valve — Powdered — S09-010A 1 2 Parts List Item Part No. Qty Description 1 160-069 1 Screw, 1/4-20 RD 2 142-002X 1 Washer, 1/4 Split-Lock 3 S62-002 1 Agitator / Slide Assy. 4 192-004 1 Lever - Powdered Soap 3 4 Reducer plugs are available for use with fine granulated soap to reduce the flow. Valves can be changed from powdered to liquid by plugging the innermost, or “bearing” hole with rubber plug, part number 125-001AK.
TDB3104, WF3204 Installation Sprayheads — Standard w/Neoprene Spray Ring Grommet Repair kit does not include sprayhead grommet. Order as a separate item. 1 4 3 2 5 9 7 10 6 8 Parts List Sprayhead Assembly S05-054B Item Part No.
TDB3104, WF3204 Installation Actuator Module Components U-Cup* (125-099) Piston* (119-227A) Duckbill Check* (198-010) Spring* (135-065) Screw (160-165) Actuator Body* (118-279) Pushbutton Assembly (S08-324) Straight Tube Connector* (169-890) Nut (110-115) Acutator Bracket (140-743) * Included in Actuator Assembly (S65-168) Metering Air Valve Maintenance Adjust Air Valve Meter Time The air valve timer is located next to the tube connector on the air valve body.
TDB3104, WF3204 Installation Troubleshooting – Metering Air Valve 8 Turn off water supplies to the unit before troubleshooting. 7 5 Item Qty.
TDB3104, WF3204 Installation Thermostatic Mixing Valve Troubleshooting Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions: • If stop valves are used, make sure that they are fully open. • Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or leaking stop valves. • Check the hot water heater output to make sure that it is at least 10° F above the set temperature.