Connection to Power Supply
The PAM 3000 is designed for use with 230V A.C/ 50Hz (standard) or 115V A.C/60Hz.
CAUTION
Before connecting the printer to the power supply, make sure that the
voltage selected on the power supply module of the printer is the same as
your main power supply !
To change the voltage setting, open the cover (3) and remove the voltage selector from
the power unit.
CAUTION !
If you have changed the operating voltage of your printer the fuses need
replacing as stated below !
230V - 2 x T 4A 115V - 2 x T 6.3A
When delivered, the correct fuses for the pre-selected operative voltage are installed.
You will find the necessary fuses for the other voltage in the accessories package.
Slide the voltage selector back into the power supply module so that the correct voltage
is visible in the lid window.
Connect the printer to a grounded outlet using the power cable supplied in the
accessories package.
Connection to a Computer
Select the required interface settings using the Setup procedure and connect the printer
to the computer by a suitable interface cable.
CAUTION !
Make sure that all connected computers and their connecting cables are
correctly grounded.