User Manual

3
3
1
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 200 degrees F. When wiring into a multi-speed blower circuit see wiring diagrams.
FOR INSTALLATION ON A VERTICAL
PLENUM SURFACE OF ANY
FORCED AIR FURNACE
INSTALLER: PLEASE LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
2
220500
220550
FLOW-THROUGH BYPASS HUMIDIFIER
12 GPD / 24V
COPPER
TUBING
PLASTIC
TUBING
Connect by-pass pipe to collar and humidifier cabinet. Using
holes at top and bottom of side panel discharge, pierce 2
self tapping screws through by-pass pipe.
Mount the self tapping saddle valve on either a cold or a hot water
pipe. A side or top mount is best to avoid clogging from pipe
sediment. Connect 1/4” O.D. tubing to the saddle valve. Copper
tubing requires a brass compression nut and brass sleeve. Plastic
tubing requires a brass insert inside the tubing and a plastic sleeve
on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR
EXCEED LOCAL CODES AND ORDINANCES.
4
Cut out center section of template and 6hole. Humidifier is self
retaining. Slide top side in first, then slide chassis down. Level
chassis and install center screws. If by-pass pipe installs to
opposite side of chassis, bend clip on chassis, remove side
discharge, and reinstall discharge to opposite side of chassis.
Install remaining four corner screws.
HIGH BOY COUNTER-FLOW LOW BOY
RETURN AIR
RETURN AIR
RETURN AIR
WARM AIR
WARM AIR
WARM AIR
WARM AIR
DRAIN
DRAIN
DRAIN
1
2
The Braeburn model 220500/220550 may be installed on
either the supply or return plenum of a forced air handling
system. The 220500/220550 is reversible for installation with
bypass duct connections on the right or left side of the
cabinet. The outer dimensions of the cabinet are 13 1/2” wide
X 15” high X 9 1/2” deep. Select a location for the humidifier
that allows for service.
AIR CLEANER
INSTALLATION: The humidifier may be mounted with the 6"
outlet to the right or left by inverting the cabinet and reversing
the positions of the distributor trough and drain pan. The
humidifier may be mounted on the warm or return air plenum
with equal efficiency.
See Typical Installations.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper
supply tubing for hot water applications
2. 6" diameter galvanized by-pass pipe
3. Electrical wire and wire nuts
4.
Current sensing relay (Braeburn Model 229050 suggested)
5. #8 self piercing sheet metal screws