Install Instructions

1
1
2
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 200 degrees F. For maximum evaporative capacity, install this humidifier on the warm air supply plenum.
When wiring into a multi-speed blower circuit see Figure 5B or 5D.
FOR INSTALLATION ON A VERTICAL
SURFACE OF THE WARM AIR PLENUM
OF ANY FORCED AIR FURNACE
INSTALLER: PLEASE LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper supply tubing for hot water applications
2. Current sensing relay (Braeburn Model 229051 suggested)
3. Junction box, 115 V. grounding outlet, cover and wire
4. 1/2” I.D. drain hose
5. #8 self piercing sheet metal screws
2
SADDLE VALVE INSTALLATION INSTRUCTIONS
Copper Pipe
1. Retract piercing pin into valve body by turning handle
counterclockwise.
2. Screw valve body into upper bracket and tighten.
3. Place rubber gasket over piercing pin.
4. Assemble saddle valve over copper pipe using enclosed screws,
nuts and lower bracket.
5. Tighten screws evenly and firmly. Brackets should be parallel.
6. Complete compression connection to saddle valve outlet.
7. Turn handle clockwise to pierce tubing and close saddle valve.
8. Turn handle counterclockwise to open saddle valve. Leave open
for several seconds to flush dirt from pipe and tubing.
Steel, Brass or Hard Plastic Pipe
1. Shut off water supply and drain pipe.
2.
Turn handle clockwise to expose piercing pin and close saddle valve.
3. Place rubber gasket over piercing pin.
4. Drill 1/8" hole in pipe using a hand crank drill to avoid shock hazard.
5. Assemble saddle valve over steel, brass or hard plastic pipe using
enclosed screws, nuts and lower bracket.
6. Tighten screws evenly and firmly. Brackets should be parallel.
7. Complete compression connection to saddle valve outlet.
8. Turn handle counterclockwise to open saddle valve. Leave open
for several seconds to flush dirt from pipe and tubing.
Threaded Pipe Fittings
1.
Turn handle clockwise to expose piercing pin and close saddle valve.
2. Seal valve body threads using pipe tape or sealant.
3. Install valve into 1/8" NPT fitting.
4. Complete compression connection to saddle valve outlet.
5. Turn handle counterclockwise to open saddle valve. Leave open for
several seconds to flush dirt from pipe and tubing.
3
COPPER
TUBING
PLASTIC
TUBING
4
220700
220750
FLOW THROUGH POWER HUMIDIFIER
18 GPD / 120V
Select location on vertical surface of warm air plenum for mounting
humidifier. Tape mounting template in place making sure the template is
level. Do not install humidifier where the blanked off ends of a cooling coil
will restrict air flow to the humidifier.
Cut out center section of template.
Open cover and remove evaporator pad assembly. Humidifier chassis is
self retaining, slide top side in first then slide chassis down. Level chassis
and install eight screws.
Mount the self tapping saddle valve on either a cold or a hot water pipe. A
side or top mount is best to avoid clogging from pipe sediment. Connect
1/4” O.D. tubing to the saddle valve. Copper tubing requires a brass
compression nut and brass sleeve. Plastic tubing requires a brass insert
inside the tubing and a plastic sleeve on the outside with a brass
compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR EXCEED
LOCAL CODES AND ORDINANCES.
Connect 1/4" water supply tube to inlet of solenoid. DO NOT USE
PLASTIC TUBING IN CONTACT WITH ANY HOT PLENUM
SURFACE OR DUCT. IF USING PLASTIC TUBING, USE INSERT
FOR PLASTIC TUBING AND PLASTIC COMPRESSION SLEEVE
(INCLUDED WITH SADDLE VALVE KIT).
Connect drain hose to 1/2" spout on humidifier cabinet using hose clamp if
necessary. Run 1/2" hose to suitable drain such as floor drain, sewer or
laundry sink. Be sure hose has continuous slope and is not kinked at
any point.