Specification Sheet

The
brighter
choice
®
Braeburn Zone
Control Systems
3 Zone Panel 140303
for Residential and Light
Commercial Applications
Braeburn Zone Control Panels feature the latest in
zone controls. Equipment and status are determined
at a glance with the monitoring LEDs built into the
panel. A supply air temperature sensor is included
with each panel to provide constant control.
Quick and Easy Installation
Braeburn zone panels are designed with the fea-
tures customers demand: easy installation, at-a-
glance status, quick and reliable wiring terminals–
all in an attractive compact panel. Braeburn, your
best source for zoning.
Product Features and Benefi ts
Sleek, low profi le design complements any system
Suitable for residential and light commercial applications
Can be used with conventional four or fi ve wire thermostats
LEDs indicate panel functionality
Quick connect terminals speed installation and reliability
Compatible with electric, gas, oil and heat pump equipment
Controls 3 heating and 2 cooling stages
Controls 2 or 3 zones
• Emergency heat switch with remote terminals for total
heat pump control
• Fan purge into last calling zone for improved
energy effi ciency.
Specifi cations
Panel Power 4 VA maximum (3.5 VA typical) for panel
System Power 4 VA (Zone Panel) + 1.0 VA per thermostat +
damper requirements, not to exceed 35 VA
Protection Electronic self resetting current limiting
Equipment Relay driven 2A at 24 VAC
Zone Damper Compatible with power open/power close, spring open/
Control power close and spring close/power open dampers
Indicators (28) Power OK, status, equipment Rh, Rc, Y1,
Y2, G, G2, W1/E/W3, W2/O-B; emergency heat,
thermostats 3X R, Y, G, W, dampers; closed or open
Switches Non HP/HP, dual fuel no/yes, reversing valve B active/O
active, fan control plenum/system, opposite mode call
timer 20/15, 2nd stage lockout none/active, priority
all/zone 1, second stage for 2 zones/2 stages.
Terminals Rh, Rc, Y1, Y2, G, G2, W1/E/W3, W2/O-B, C,
E-Heat, SA1, SA2 panel power (2) and R, Y, G, W, C,
PO, C, PC for each zone
Settings Large display for high temperature and low temperature
cut-out, purge status, supply temperature
Toll-Free 866.268.5599 (U.S.) +1.630.844.1968 (Outside the U.S.) www.braeburnonline.com