Specifications

5
INSTALLATION
It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to
change without notice. Please consult with your dealer to confirm the specifications of the model selected.
Flexible Connector (Side & Top Series)
The flexible connector has not been fitted at the factory. It is intended to be fitted
on site to allow for better alignment to the ductwork.
1. Position the flexible connector (part A) with the seam to the bottom.
The corners of the skirt will need to be slit approximately 20mm to prevent
bulging at the corners.
2. The aluminium straps B,C,D & E fit inside the skirt.
3. Using one of the aluminium straps, mark and drill the rivet holes.
Note - The bottom edge of the strap is intended to be level with the edge of the
opening in the cooler.
4. Fit strap (part B) using the 5 of the rivets supplied, starting from the centre and
working towards the ends.
The skirt must be tucked under the aluminium strap before riveting.
5. Fit Straps C & D before fitting strap E.
Seal with Silicone after completion.
FITTING INSTRUCTIONS
A
Top Edge
B
E
C
D
A = Flexible Connector
B=TopStrap
C = Side Strap
D = Side Strap
E = Bottom Strap
3
250
A
B