Product manual

Serial Solutions Range Product
Manual
© Copyright Brainboxes Limited 2010 Page 33 of 47
6.4. Baud rate test application
To test to see if a specific baud rate is supported by one of our cards, the Baud rate test application can be
used. You simply put the Baud rate details into the program and then click calculate and the details will be
output. This software is supplied on the Serial Solutions CD.
The following settings need to be applied for specific Brainboxes products
If you have a PM-121 or CC-530/525 you will need to select the 950 UART type.
If you have any UC card set the UART type to Versatile UART CID = 0x10
If you have any other PM card set the UART type to Versatile UART CID = 0x01
The last option is for USB devices so is not applicable for the Serial Solutions software product
ranges.
The crystal frequency will also need to be set to a specific value for the card that you are using. For UC and
PM cards the frequency is 1475600.