Installation Guide

DO NOT stretch the connector to make it t.
Connector must be long enough to allow the
appliance to be positioned at its farthest anticipated
connected distance from the gas supply without
stretching, twisting or bending smaller that a 1-1/2
internal diameter (diameter of a golf ball).
DO NOT trap connector against sharp edges
or corners.
CAUTION: DO NOT kink, twist or bend connector sharply.
6. Turn manual shut-off valve on to allow gas to
enter system.
WARNING: DO NOT TURN ON APPLIANCE until all
connections have been leak tested!
WARNING: DO NOT USE matches, candles, open
ames or other sources of ignition to leak test
connections!
7. Test all connections with leak test solution provided,
or with clear soap and water solution; bubbles will
indicate a leak. If a leak is detected, turn off gas
supply before further tightening connections.Water
rinse and towel dry connector once test is complete.
8. Wait at least 10 minutes to be certain that all vapors
have dissipated. If leak test conrms connections do
not leak gas, and you do not smell any gas,
THEN light pilot(s) and turn on appliance.
Tools Needed for Installation:
• (2) 10” adjustable wrenches
• Pipe dope or gas pipe thread tape
• Leak detection solution
BrassCraft Mfg. , 39600 Orchard Hill Place Novi, Michigan 48375-5331
TOLL-FREE: 877.272.7755 FAX: 248.305.6011 www.brasscraft.com
©2009, 2011 BrassCraft Mfg.
325.01 11/11
X