Product Manual

Operation Instructions
16
Vacuuming Operation & Safety
When operating, engine should run at full RPM
Using a sweeping motion, point hose inlet towards debris and sweep back and forth to remove
debris.
Keep hand, feet and body parts away from hose inlet, discharge chute and any moving parts.
Keep hose straight and avoid sharp bends in hose during use. This will prevent clogs.
Keep nozzle close to debris while using a sweeping motion, but do not bury or block the air
flow of the nozzle.
Before shutting unit off, run and evacuate the entire system, hose and blower housing
Stopping the Engine
Stop the engine using the following steps:
1. Turn the On/Off engine switch to OFF position located on engine.
2. Allow the engine to cool for at least 5 minutes before moving to storage or transporting. A hot
engine can be a fire hazard.
Unclogging Unit
Unclogging hose: If decreased suction is present, there maybe a blockage in hose.
1. With engine running and securely mounted, stretch hose out fully to dislodge.
2. If the hose does not clear the clog by stretching, you will need to turn OFF engine and wait for
impeller to STOP completely.
3. Disconnect spark plug wire and battery cables if applicable.
4. Remove the hose assembly. Wearing gloves, clear any debris that is clogging the hose.
5. Once clog is cleared, reassemble and reconnect the spark plug wire to resume operation.
Unclogging Housing or Exhaust Chute: If decreased suction is present, there may be a blockage
1. Turn engine OFF.
2. Wait for impeller to completely STOP.
3. Disconnect spark plug wire and battery cables if applicable.
4. Remove the hose assembly from housing to locate clog.
5. If possible clear clog from housing intake opening.