5
2.3 Water system
Water hardness : min. 5 _dH (0,9 mmol/l)
Min. water pressure (supply) : 50 kPa (0,5 bar)
Max. water pressure (supply) : 1000 kPa (10 bar)
Flowrate : 5,5 l/min
Conductivity : q100 m Siemens/cm
Model Number of elements
in HW−tank
Volume hot water
tank
Buffer capacity
hot water
Hour capacity hot
water
B5 HW
2
50l
22l
ca. 22 l
B5 HW
5
5,0 l 2,2 l
ca. 55 l
B10 HW
2
57l
29l
ca. 22 l
B10
HW
5
5,7
l
2
,
9
l
ca. 55 l
B20 HW
2
70l
42l
ca. 22 l
B20
HW
5
7,
0
l
4,
2
l
ca. 55 l
Table 3 Water values B HW
2.4 Environmental conditions
In view of danger of freezing the machine may never be placed in rooms where the temperature can
fall below 0_C.
With a maximum allowed environmental temperature of 40_C a good operation of the machine is
guaranteed.
2.5 Recommended cleaning and descaling materials
Cleaning material : CLEANER
Descaler : RENEGITE
CAUTION!
Before use first read the instructions on the packing.
See chapter 9. for ordering cleaner and descaler.
2.6 Recommended coffee and filter paper
For this machine the use of normal grind is recommended. Use the amount of ground coffee indicated
at the coffee calculator (§ 4.1.4 / 7.3.11) dependent on your preference.
Exclusively use the provided Bravilor Bonamat
[
filter paper or filter paper of the same quality. See
chapter 9. for ordering consumable goods.