Operation Manual

GB
version ECopyright Bravilor Bonamat B.V.42 1.0
8.2 Coffeemaking system
LIST OF MALFUNCTIONS
Symptom: Possible cause: Actions:
1. After pressing the ’amount
key’ the machine beeps
every other second.
Spray head outlet is not
positioned properly in relation to
the filter unit (see display).
Position the spray head outlet
correct above the filter unit.
Container is not positioned
properly (see display).
Place the container in the
correct position.
Call in service.
2. Filter unit runs over. The filter paper is doubled. Check the filter paper.
Due to a combination of soft
water (<7_ DH), too finely
ground coffee or the use of flat
filter paper the water cannot go
Make use of the filter cone with
cone filter paper and/or use a
courser ground coffee.
filt
er
paper
th
e
wa
t
er
canno
t
go
through the coffee / filter paper
quickly enough.
Adjust the coffeemaking
capacity, see § 7.3.9.
3. Coffee is too cold. Plug of the container is not
connected to the column.
Connect the plug of the
container to the socket on the
column (Q.).
Container switch is not on. Switch on the container switch
(AA.).
Internal fuse has blown due to
overload.
Call in service.
4. Coffee is too strong / not
strong enough.
Incorrect coffee dosage. Set the correct dosage using
the coffee calculator, see
§ 4.1.4.
Incorrect setting of the amount
of water.
Set the correct amount of water,
see § 7.3.1.
The mixer pipe is not there. Insert the mixer pipe (X.) into
the container.
5. Too much / too little coffee
in the container.
Incorrect setting of the amount
of water.
Set the correct amount, see
§ 7.3.1.
6. Coffee grounds in the coffee
container.
Filter paper torn or doubled. Check the filter paper.
7. After the container has been
filled the symbol of the filter
unit is still lit.
Drip time too long. Set the drip time again, see
§ 7.3.10.