Specifications

ECopyright Bravilor Bonamat B.V.
1.8 Hardware protections
The machine is equipped with a number of hardware
protections. These protections ensure that no
dangerous situations can arise, such as overheating
and/or water in the machine.
1.8.1 Backflow protection
The water from the magnetic valve is sprayed
against the cover through a pipe in the cold water
tank. Then it flows into the cold water tank. In this
way, water is prevented from flowing back into the
system and getting into the water system when the
water pressure is released from the magnetic valve.
1.8.2 Boiling protection
The boilingdry protection is mounted on the outside
of the boiler by means of two Klixons. If the boiler,
for whatever reason, is not switched off by the
control, the Klixons make sure that the voltage on
the element is mechanically switched off to prevent
overheating.
1.8.3 Overflow protection
This protection is located in the cold water tank and
ensures that, when the water level is too high,
excess water is passed through the overflow hose at
the bottom of the machine.