Specifications

ECopyright Bravilor Bonamat B.V.
1.9 Software protection
The machine has been equipped with a number of
software protections; the software monitors all inputs
and outputs of the machine throughout the process.
If nonallowed situations arise, the software will
intervene. This intervention results in the machine
being switched off and an error message being
shown on the display.
Fig. 9 LCD display with error message
ERROR LIST
Error 1 not applicable
Error 2 Temperature in boiler too high:
If the temperature sensor (NTC) measures
a value that is outside its range (0 Ohm or
infinity), the machine is switched off and
’Error 2’ appears in the LCD display. This
also applies if the boiling protection (see
hardware protection) is activated.
Error 3 not applicable
Error 4 not applicable
Error 5 not applicable
Error 6 Magnetic valve opened too long:
If, for whatever reason, the process of filling
the float tank takes too long, the machine is
switched off and ’Error 6’ appears in the LCD
display.
Error 7 Wrong Chip card:
In a number of cases, it is possible to place a
chip card in a chip card reader. This is
present on the keyboard. Any data present
can be downloaded or uploaded. If the
software on this chip card does not
correspond with the software in the machine,
’Error 7’ appears in the LCD display.
Error 8 Communication error between both prints:
There is constant communication during
machine startup and during use. This is
done via the flatcable between the keyboard
and the main board. If communication is
impossible, ’Error 8’ appears in the LCD
display.
Error 9 Pump motor rotates too slow or does not
rotate at all:
The pump motor is rotating during machine
startup and during use. The light sensor
detects no or too little pulses and ’Error 9’ will
appear in the LCD display.