Unit installation
10-2
RLC-3 V1.80 Copyright © 1998 Link Communications Inc. 9/17/98
082: Set Up a Scheduler Event
This command sets up when a scheduler event will occur and what will happen at that time.
<082> ss ccc mm Hourly Event
<082> ss ccc hh mm p Daily Event
<082> ss ccc w hh mm p Weekly Event
<082> ss ccc dd hh mm p Monthly Event
<082> ss ccc nn dd hh mm p Yearly Event
Parameters:
- 082 is the default command name.
- SS is the number of the scheduler slot to set up [00..99]
- CCC is the number of the command to be executed by the scheduler
Note: The command that the scheduler executes must not require any data
(like is normally entered after the "*" key), because there is no way to supply
that data. If you want the scheduler to execute a command that requires
data, you must make the scheduler call a user macro, then program that
macro to call the command with the appropriate data.
- MM is how many minutes after the hour the event will occur
- HH is the hour that the event will occur (12 hour time)
- P is 0 to indicate A.M. or 1 to indicate P.M.
- W is the day of the week
Number Day
1 Sunday
2 Monday
3 Tuesday
4 Wednesday
5 Thursday
6 Friday
7 Saturday
- DD is the day of the month
- NN is the month of the year