Unit installation

13-13
RLC-3 V1.80 Copyright © 1998 Link Communications Inc. 9/17/98
119: Set Allowed Numbers Table Slot
This command allows you to set one of the slots in the allowed numbers table. For a description of
this table and how to use it, see the explaination of the dialing tables before Command 110.
<119> sss Clear slot sss
<119> sss d..d Program slot sss
Parameters:
- 119 is the default command name.
- SSS is the slot number (000..499)
- D..D is the area code/prefix (do not include the last four digits of the phone
number). The '#' digit is a wildcard that matches any digit.
Defaults:
- Slot 000 is programmed to “###”, which allows all seven digit numbers.
120: Recall Allowed Numbers Table Slot
This command allows you to recall the contents of one of the slots in the allowed numbers table.
For a description of this table and how to use it, see the explaination of the dialing tables before
Command 110.
<120> sss
Parameters:
- 120 is the default command name.
- SSS is the slot number (000..499)