Unit installation
13-14
RLC-3 V1.80 Copyright © 1998 Link Communications Inc. 9/17/98
121: Set Nuisance Numbers Table Slot
This command allows you to set one of the slots in the nuisance number table. For a description of
this table and how to use it, see the explaination of the dialing tables before Command 110.
<121> sss Clear slot sss
<121> sss d..d Program Slot sss
Parameters:
- 121 is the default command name.
- SSS is the slot number (000..099)
- D..D is the whole number to be blocked (do include the last four digits of the phone
number). The '#' digit is a wildcard that matches any digit.
Defaults:
- Slot 000 is programmed to “###” to block three digit numbers (which isn’t really
necessary and has no effect) and slot 001 is programmed to “####” to block four digit numbers.
122: Recall Nuisance Numbers Table Slot
This command allows you to recall the contents of one of the slots in the nuisance number table.
For a description of this table and how to use it, see the explaination of the dialing tables before
Command 110.
<122> sss
Parameters:
- 122 is the default command name.
- SSS is the slot number (000..099)
- D..D is the whole number to be blocked (do include the last four digits of the phone
number). The '#' digit is a wildcard that matches any digit.