Unit installation

14-23
RLC-3 V1.80 Copyright © 1998 Link Communications Inc. 9/17/98
141: Control/Recall RBI-1 Output Lines
The Doug Hall RBI-1 has eight open collector output lines that can be used to control other
hardware, such as antenna switches. Those output lines can be controlled with this command. See
the RBI-1 manual for more information about their current sink limits and other specifications.
<141> X Recall State of Output ‘X’
<141> X 1 Turn Output ‘X’ On
<141> X 0 Turn Output ‘X’ Off
Note:
When an output line is turned on or off using this command, there will be a slight delay
(about a second) before the change will actually take place. Because of the delay, this
command cannot be used to quickly pulse an output line. See commands 093 and 094
which use the output lines on the I/O board if you need pulses.