Transmitter Mini-Hang Timer:
This timer holds the transmitter PTT active for a minimum time after any keying source (connected
receiver, synthesized voice, tone, cw, DVR message, etc) goes inactive. It can be used to keep the
transmitter from dropping out immediately after a message. To control the hang time after a
connected receiver unkeys, you can also use the normal hang timers (016..023); the actual hang
time will be the longer of the two.
- This timer is programmed in 10mS increments from 000-9999
Timer Number Definition Defaults
060 Mini-Hang Timer, Transmitter 1 1/2 sec (50)
061 Mini-Hang Timer, Transmitter 2 "
062 Mini-Hang Timer, Transmitter 3 "
063 Mini-Hang Timer, Transmitter 4 "
064 Mini-Hang Timer, Transmitter 5 "
065 Mini-Hang Timer, Transmitter 6 "
066 Mini-Hang Timer, Transmitter 7 "
067 Mini-Hang Timer, Transmitter 8 "