Unit installation

4-11
RLC-3 V1.80 Copyright © 1998 Link Communications Inc. 9/17/98
Pending ID Timer:
This timer times inner activity ID timer so a proper Pending ID can be send during activity.
- This timer is programmed in 1Sec increments from 001-9999
- If a timer value of 000 is entered, the controller will never send a rotating ID.
- This timer should normally be set shorter than the initial ID timer (one minute shorter works
well). You may need to make sure that the length of this timer plus the length of the impolite ID
timer is less than 10 minutes to meet requirements for ID timing.
Timer Number Description Defaults
116 Pending ID Timer, Transmitter 1 9 min (540)
117 Pending ID Timer, Transmitter 2 "
118 Pending ID Timer, Transmitter 3 "
119 Pending ID Timer, Transmitter 4 "
120 Pending ID Timer, Transmitter 5 "
121 Pending ID Timer, Transmitter 6 "
122 Pending ID Timer, Transmitter 7 "
123 Pending ID Timer, Transmitter 8 "