Unit installation
4-12
RLC-3 V1.80 Copyright © 1998 Link Communications Inc. 9/17/98
Timeout Timers:
This timer times the how long each receiver has been active. If the receiver is active longer than
the length of this timer, it is disabled until it goes inactive, and its time out message (see list of
macros in Chapter 8) is sent out all transmitters that are connected to it. It is reset and the time out
clear message is sent when a timed out receiver goes inactive.
- This timer is programmed in 1 second increments from 001-9999
- If a timer value of 000 is entered, the controller will never time-out.
Timer Number Description Defaults
124 Time Out Timer, Receiver 1 3 Min. (180)
125 Time Out Timer, Receiver 2 "
126 Time Out Timer, Receiver 3 "
127 Time Out Timer, Receiver 4 "
128 Time Out Timer, Receiver 5 "
129 Time Out Timer, Receiver 6 "
130 Time Out Timer, Receiver 7 "
131 Time Out Timer, Receiver 8 "