Dial Tone Timers:
These timers are used to limit how long the dial tone will run. The dial tone can also be stopped by
other things, such as a DTMF character being entered on the port the dial tone is being sent out of
or the preaccess timer expiring (since indicating that a link has been preaccessed is what dial tone is
used for most). If you want to generate dial tone that can't be stopped by any of these things, use
command C040 and generate a two tone chord with frequencies of 350 and 440 Hz.
- This timer is programmed in 1Sec increments from 001-9999
- If a timer value of 000 is entered, this timer will never stop the dial tone.
Timer Number Description Defaults
132 Dial Tone Timer, Transmitter 1 8 sec. (008)
133 Dial Tone Timer, Transmitter 2 "
134 Dial Tone Timer, Transmitter 3 "
135 Dial Tone Timer, Transmitter 4 "
136 Dial Tone Timer, Transmitter 5 "
137 Dial Tone Timer, Transmitter 6 "
138 Dial Tone Timer, Transmitter 7 "