Preaccess Timers:
These timers control how long the "window" of access is between when you enter the preaccess
code and when you have to enter a DTMF digit or be locked out. It starts running again as soon as
each DTMF digit is released, and will lock you out if it expires. When it expires, it throws away
whatever DTMF digits have been entered so far and won't accept any more commands until the
controller is accessed again. It also stops the dial tone when it expires (if it expires before the dial
tone timer does).
- This timer is programmed in 1Sec increments from 001-9999
- If a timer value of 000 is entered, this timer will never expire.
Timer Number Description Defaults
140 Preaccess Timer, Port 1 8 sec. (008)
141 Preaccess Timer, Port 2 "
142 Preaccess Timer, Port 3 "
143 Preaccess Timer, Port 4 "
144 Preaccess Timer, Port 5 "
145 Preaccess Timer, Port 6 "
146 Preaccess Timer, Port 7 "
147 Preaccess Timer, Port 8 "